2Pfg 1169/08 Requirements for Cable

2Pfg 1169/08 Requirements for Cable

Introduction
Product Description
2Pfg 1169/08 is suitable for DC side flexible single-core cable (conductor/conductor, non-grounded system) of photovoltaic system with maximum allowable voltage DC 1.8kV. Dc 1.8kV, AC U0/U 0.6/1kV
Conductor: One, conforming to EN60228, conductor shall be grade 5. Single wire must be tinned, preferably 2.5,4,6,10,16mm²
Insulation: Suitable halogen-free material shall be applied to the conductor, with a minimum of 0.5 mm
Sheath: Suitable halogen-free material to cover the conductor, minimum not less than 0.5,mm
Packing Details: Wooden PalletWooded Drum/as customers requirement
Rated voltage: DC 1.8kV, AV 0.6/1kV
Technical parameter
Single core photovoltaic cable comprehensive data
Type Specification mm Tinned conductor (mm) Insulation process (mm) Sheath operation(mm) 20 ° C Conductor resistance ≤ (Ω/km)
Number of strands * Number of strands/wire diameter Approximate outside diameter Nominal thickness Thinner point ≥ Calculated outside diameter Nominal thickness Thinner point ≥ Calculated outside diameter
PV1-F 1.5 1×30/0.25 1.6 0.6 0.5 2.9 0.7 0.5 4.5 13.7
2.5 1×49/0.25 2.0 0.7 0.5 3.5 0.8 0.5 5.3 8.21
4 1×50/0.3 2.45 0.75 0.5 4.0 0.8 0.5 5.7 5.09
6 7×11/0.3+2/0.3 3.4 0.75 0.5 4.9 0.8 0.5 6.6 3.39
10 7×11/0.4 4.3 0.9 0.5 6.2 1.0 0.5 8.4 1.954
16 7×18/0.4 5.6 0.9 0.5 7.5 1.0 0.5 9.7 1.24
25 7×28/0.4 7.0 1.0 0.5 9.1 1.2 0.5 11.7 0.795
35 12×23/0.4 8.6 1.2 0.5 11.1 1.4 0.5 14.1 0.565