IEC 62930 Electric Cables for Photovoltaic Systems

IEC 62930 Electric Cables for Photovoltaic Systems

Introduction
Product Description
Conductor: Copper, and single conductor wire shall be tinned according to IEC 60228. The wire shall be covered with a continuous tin coating. For cables directly connected to photovoltaic modules, conductor grades shall conform to IEC 60228 Level 5, and conductors of Class 2 are permitted for cables intended for fixed installation and not directly connected to photovoltaic modules
Insulation: crosslinked compounds that meet the requirements set out in IEC 62930
Sheath: A crosslinked compound that meets the requirements specified in IEC 62930 shall be black and run throughout the sheath
Packing Details: Wooden PalletWooded Drum/as customers requirement
Rated voltage: 1.5kV DC
Technical parameter
Size Cross Section
mm2
Conductor Structure
mm
Outer Diameter
mm
Max. DC Resistance at
20 
Ω/km
Rated Voltage
V
Rated Current
A
1*1.5 1.5mm2 30/0.25 4.9 13.3 1500V 30
1*2.5 2.5mm2 50/0.25 5.45 7.98 1500V 41
1*4.0 4mm2 56/0.30 6.1 4.75 1500V 55
1*6.0 6mm2 84/0.30 7.2 3.39 1500V 70
1*10.0 10mm2 142/0.30 9 1.95 1500V 98
1*16.0 16mm2 228/0.30 10.2 1.24 1500V 132
1*25.0 25mm2 361/0.30 12 0.795 1500V 176
1*35.0 35mm2 525/0.30 13.8 0.565 1500V 218
1*50.0 50mm2 720/0.30 14.8 0.393 1500V 280
1*70.0 70mm2 988/0.30 16.9 0.277 1500V 350
1*95.0 95mm2 1349/0.30 18.7 0.21 1500V 410
1*120.0 120mm2 1691/0.30 20.7 0.164 1500V 480
Size (mm2) Strand No./size Conductor Strand
OD.(mm)
Cable OD.
(mm)
Electrical Resistance at 20 (Ω/km) Amp rating 60
2*1.5mm2 30/0.25 1.58 4.6x9.4 13.7 30
2*2.5mm2 50/0.25 2.02 5.1x10.4 8.21 42
2*4mm2 56/0.29 2.35 5.5x11.2 5.09 55
2*6mm2 84/0.29 3.2 6.2x12.6 3.39 70
2*10mm2 142/0.3 4.6 7.8x15.2 1.95 98
2*16mm2 228/0.3 5.6 9.3x18.8 1.24 132