15kV SAC Cable IEC 60502-2 , ICEA S-66-524 | |||||||
Nominal Size | Min.No. of Wires |
Covering Thickness | Cable Diameter | Min. Breaking Load | Weight | ||
Conductor Shield | Inner Layer | Outer Layer | |||||
mm² | No. | mm | mm | mm | mm | kgf | kg/km |
3-Layer 15kV AAC/XLPE/XLPE | |||||||
25 | 6 | 0.60 | 1.91 | 1.91 | 15.2 | 3762 | 218 |
35 | 6 | 0.60 | 1.91 | 1.91 | 16.2 | 5177 | 258 |
50 | 6 | 0.60 | 1.91 | 1.91 | 17.3 | 7011 | 307 |
70 | 12 | 0.60 | 1.91 | 1.91 | 19 | 10354 | 387 |
95 | 15 | 0.60 | 1.91 | 1.91 | 20.8 | 13727 | 482 |
120 | 15 | 0.60 | 1.91 | 1.91 | 22 | 17339 | 564 |
150 | 15 | 0.60 | 1.91 | 1.91 | 23.7 | 21033 | 660 |
185 | 30 | 0.60 | 1.91 | 1.91 | 25.3 | 26732 | 780 |
240 | 30 | 0.60 | 1.91 | 1.91 | 27.6 | 34679 | 968 |
3-Layer25kV AAC/XLPE/XLPE | |||||||
25 | 6 | 0.70 | 3.18 | 3.18 | 20.1 | 3762 | 351 |
35 | 6 | 0.70 | 3.18 | 3.18 | 21.1 | 5177 | 398 |
50 | 6 | 0.70 | 3.18 | 3.18 | 22.2 | 7011 | 455 |
70 | 12 | 0.70 | 3.18 | 3.18 | 23.9 | 10354 | 548 |
95 | 15 | 0.70 | 3.18 | 3.18 | 25.7 | 13727 | 657 |
120 | 15 | 0.70 | 3.18 | 3.18 | 26.9 | 17339 | 748 |
150 | 15 | 0.70 | 3.18 | 3.18 | 28.6 | 21033 | 856 |
185 | 30 | 0.70 | 3.18 | 3.18 | 30.2 | 26732 | 989 |
240 | 30 | 0.70 | 3.18 | 3.18 | 32.5 | 34679 | 1195 |
3-Layer 35kV AAC/XLPE/XLPE | |||||||
25 | 6 | 0.70 | 4.45 | 3.18 | 22.6 | 3762 | 433 |
35 | 6 | 0.70 | 4.45 | 3.18 | 23.6 | 5177 | 485 |
50 | 6 | 0.70 | 4.45 | 3.18 | 24.7 | 7011 | 545 |
70 | 12 | 0.70 | 4.45 | 3.18 | 26.4 | 10354 | 645 |
95 | 15 | 0.70 | 4.45 | 3.18 | 28.2 | 13727 | 761 |
120 | 15 | 0.70 | 4.45 | 3.18 | 29.4 | 17339 | 856 |
150 | 15 | 0.70 | 4.45 | 3.18 | 31.1 | 21033 | 971 |
185 | 30 | 0.70 | 4.45 | 3.18 | 32.7 | 26732 | 1110 |
240 | 30 | 0.70 | 4.45 | 3.18 | 35 | 34679 | 1324 |
15kV SAC Cable IEC 60502-2 , ICEA S-66-524 | |||||||
Nominal Size | Min.No. of Wires |
Covering Thickness | Cable Diameter | Min. Breaking Load | Weight | ||
Conductor Shield | Inner Layer | Outer Layer | |||||
mm² | No. | mm | mm | mm | mm | kgf | kg/km |
3-Layer 15kV AAC/XLPE/HDPE | |||||||
25 | 6 | 0.60 | 1.91 | 1.91 | 15.2 | 3762 | 221 |
35 | 6 | 0.60 | 1.91 | 1.91 | 16.2 | 5177 | 261 |
50 | 6 | 0.60 | 1.91 | 1.91 | 17.3 | 7011 | 310 |
70 | 12 | 0.60 | 1.91 | 1.91 | 19 | 10354 | 390 |
95 | 15 | 0.60 | 1.91 | 1.91 | 20.8 | 13727 | 486 |
120 | 15 | 0.60 | 1.91 | 1.91 | 22 | 17339 | 568 |
150 | 15 | 0.60 | 1.91 | 1.91 | 23.7 | 21033 | 664 |
185 | 30 | 0.60 | 1.91 | 1.91 | 25.3 | 26732 | 785 |
240 | 30 | 0.60 | 1.91 | 27.6 | 34679 | 973 | |
25kV SAC Cable IEC 60502-2 , ICEA S-66-524 | |||||||
Nominal Size | Min.No. of Wires |
Covering Thickness | Cable Diameter | Min. Breaking Load | Weight | ||
Conductor Shield | Inner Layer | Outer Layer | |||||
mm² | No. | mm | mm | mm | mm | kgf | kg/km |
3-Layer 25kV AAC/XLPE/HDPE | |||||||
25 | 6 | 0.70 | 3.18 | 3.18 | 20.1 | 3762 | 356 |
35 | 6 | 0.70 | 3.18 | 3.18 | 21.1 | 5177 | 404 |
50 | 6 | 0.70 | 3.18 | 3.18 | 22.2 | 7011 | 461 |
70 | 12 | 0.70 | 3.18 | 3.18 | 23.9 | 10354 | 555 |
95 | 15 | 0.70 | 3.18 | 3.18 | 25.7 | 13727 | 664 |
120 | 15 | 0.70 | 3.18 | 3.18 | 26.9 | 17339 | 755 |
150 | 15 | 0.70 | 3.18 | 3.18 | 28.6 | 21033 | 864 |
185 | 30 | 0.70 | 3.18 | 3.18 | 30.2 | 26732 | 997 |
240 | 30 | 0.70 | 3.18 | 3.18 | 32.5 | 34679 | 1203 |
35kV SAC Cable IEC 60502-2 , ICEA S-66-524 | |||||||
Nominal Size | Min.No. of Wires |
Covering Thickness | Cable Diameter | Min. Breaking Load | Weight | ||
Conductor Shield | Inner Layer | Outer Layer | |||||
mm² | No. | mm | mm | mm | mm | kgf | kg/km |
3-Layer 35kV AAC/XLPE/HDPE | |||||||
25 | 6 | 0.70 | 4.45 | 3.18 | 22.6 | 3762 | 439 |
35 | 6 | 0.70 | 4.45 | 3.18 | 23.6 | 5177 | 491 |
50 | 6 | 0.70 | 4.45 | 3.18 | 24.7 | 7011 | 552 |
70 | 12 | 0.70 | 4.45 | 3.18 | 26.4 | 10354 | 652 |
95 | 15 | 0.70 | 4.45 | 3.18 | 28.2 | 13727 | 768 |
120 | 15 | 0.70 | 4.45 | 3.18 | 29.4 | 17339 | 864 |
150 | 15 | 0.70 | 4.45 | 3.18 | 31.1 | 21033 | 980 |
185 | 30 | 0.70 | 4.45 | 3.18 | 32.7 | 26732 | 1119 |
240 | 30 | 0.70 | 4.45 | 3.18 | 35 | 34679 | 1334 |
22.9kV ACSR/AW-OC Aerial Insulated Cables IEC 60502-2 | |||||||
Nominal Size | Min.No. of Wires |
Covering Thickness | Cable Diameter | Min. Breaking Load | Weight | ||
Conductor Shield | Inner Layer | Outer Layer | |||||
mm² | No. | mm | mm | mm | mm | kgf | kg/km |
22.9 kV ACSR/AW-OC/XLPE | |||||||
32 | 6/SB | 1/2.6 | 7.2 | 3 | 13.2 | 1090 | 210 |
58 | 6/SB | 1/3.5 | 9.7 | 3 | 15.7 | 1900 | 330 |
95 | 6/SB | 1/3.5 | 12 | 3.5 | 19 | 2360 | 530 |
160 | 18/SB | 1/3.2 | 15.4 | 4 | 23.4 | 3080 | 730 |
240 | 18/SB | 1/4.0 | 18.9 | 4 | 27 | 4500 | 1040 |